Designed to travel everywhere you do, the VitalCareTM 506NV3 series patient monitor with integrated carry-handle attaches quickly and easily to a rolling stand. Available in multiple configurations – with choice of Criticare or Nellcor oximetry – the 506NV3 patient monitors provide maximum versatility and cost-effectiveness. New smart battery management allows up to 100 NIBP measurements on a single charging. With a compact design that is easily setup for spotcheck or continuous monitoring, the 506NV3 patient monitor adapts readily to hospital, clinic and transport requirements.NIBP, predictive Alaris TurboTemp® temperature—and exceptional ease of use make our 506NV3 series monitors the perfect solution to your clinical challenges. The 506NV3 TurboTemp® series is designed for facilities that are maintaining compatibility with IVAC type P850A probe covers and Alaris TurboTemp® probes. The lightweight 506NV3 monitor with integrated carry-handle attaches quickly and easily to IV pole mount or rolling stand. Available in configurations with or without internal printer, with optional CSI DOX™ or Nellcor OxiMax pulse oximetry—the 506NV3 series provides maximum versatility and cost-effectiveness. Features and Benefits
- Proprietary ComfortCuff ™ NIBP measures on inflation for faster, more comfortable readings.
- Choice of Criticare DOX™ digital SpO2 technology or Nellcor OxiMax™ SpO2 technology.
- Audible and visual alarms are adjustable providing instant notification the way you need them.
- Optional FILAC FasTemp™ predictive temperature for quick, accurate measurements.
- Optional internal printer for on-demand, automatic interval, trends or multi-patient reports.
Technical Specifications
Non-Invasive Blood Pressure
- Technique: Oscillometric measure upon inflation.
- Measurement Time: <40 seconds typical; 0 to 300mmHg;
- Standard adult cuff.
- Automatic Measurement.
- Cycles: 1 - 60 minute; 2 - 4 hour; STAT.
- Inflation Pressure Range: 30 to 300mmHg (Adult)
- 30 to 150mmHg (Pediatric)
- 20 to 150mmHg (Neonate)
- Resolution: 1mmHg.
- Clinical Accuracy: SP-10:2002.
- Transducer Accuracy: ±2mmHg or ±2% of reading, whichever is greater, over full range.
- STAT mode: 5 minutes of consecutive readings.
Pulse Oximetry
- Range: 1% to 99%
- Resolution: 1%
- Accuracy (DOX only): 70% to 99% range: ±2%;
- 50% to 69% range: ±3%; <50%: unspecified
- Accuracy (OxiMax Only): 70% to 99% range: ±2%; <70%: unspecified
- Method: Dual wavelength LED
- Audio: Tone with each detected pulse; pitch varies with saturation
Heart (Pulse) Rate
- Range: 20 to 300bpm.
- Accuracy (DOX only): Greater of ±1bpm or ±1%, of reading.
- Unspecified for <30 or >240 bpm.
- Accuracy (OxiMax only): Greater of ±1bpm or ±1%, of reading.
- Unspecified for <30 or >240 bpm.
- Update Time: Every second.
- Resolution: 1bpm.
- Pulse Volume: 10 levels or Off.
Temperature (optional)
- Type: Alaris TurboTemp®Method: Predictive or ContinuousChannels: 1
- Predictive Mode Range: 96.0° to 106° F (35.6°> to 41.1°C)
- Continuous Mode Range: 80:0° to 106° F (26.7° to 41.1° C)
- Accuracy: ±0.2°F (±0.1°C) (measured in calibrated water bath in continuous mode)
- Resolution: 0.1° F or 0.1° C
- Response Time: 10 seconds typical (oral measurements)
- Probes: CAT1544 Oral, CAT 1545 Rectal
- Probe Covers: CAT 447 (P850A)
Alarms
- Indication: Audible; Visual
- Volume: 10 levels or Off
- Silence: Yes; 2 minutes or permanent
Trend Memory
- Memory: Last 24 hours
- Parameters: SpO2, pulse rate, NIBP, temperature
- Report Types: Single Patient or Multi-patient;
- Selectable formats
Displays
- Type: LED
- Parameters: NIBP, SpO2; temperature, pulse rate; pulse bar
- Status: Alarm Silence; Sensor; Low Battery; External
- Power; Patient Size
- Text: Alphanumeric LCD
- Languages: English, French, German, Italian, Portuguese, Spanish, Dutch, Danish
System Output
- Com Port: Serial, RS 232-compatible
Printer
- Type: Thermal array
- Tabular Mode: 1 - 60 minute intervals; 2 - 24 hour intervals;
- Auto on BP; Auto on Alarm, Off
Mechanical
- Weight: Base unit with battery: 6.95 lb; 3.15kg
- Size: Base unit: 8.7" (H) x 7.1" (W) x 6.5” (D); 22cm (H) x 18cm (W) x 16.5cm (D)
Power Requirements
- Voltage: 100 to 240 VAC, 50 to 60 Hz
- Battery: Sealed lead acid; Life: 8 hours
- Rechargeable: 6 hours
Environmental
- Operating Temperature: 32º to 113º F; 0º to 45º C
- Storage Temperature: 23º to 122º F; -5º to 50º C
- Operating Humidity: 15% to 90%, non-condensing
Classification
- Type of Protection: Class I equipment
- Degree of Protection: Type CF defibrillator-proof equipment
- Protection against Ingress: IPX1 rating, Drip-Proof Equipment
Warranty Information
Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod
tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam,
quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo
consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse
cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non
proident, sunt in culpa qui officia deserunt mollit anim id est laborum.